Why output drops
Scale on the evaporator plate insulates the surface the ice forms on, so each cycle takes longer and cubes come out thin. A spent water filter reduces flow, and a dirty air-cooled condenser in a hot back bar reduces the machine's ability to reject heat.
None of these look like a refrigeration failure, and none are fixed by adding gas.
What servicing should include
Descaling of the water circuit and evaporator, sanitising of the bin and chute, filter replacement, condenser cleaning, and a check of the harvest cycle and sensors.
Ice is food. A machine that has never been sanitised is a hygiene problem before it is a capacity problem.
Setting the frequency
Water hardness varies across the Helderberg and the coastal strip, so two bars with identical machines may need different schedules. Busy venues typically need servicing every three to six months; quieter sites can stretch further.
Schedule a service before the festive season rather than during it. A machine that fails in December is far more disruptive than one serviced in October.
Questions
Can I descale an ice machine myself?
Manufacturer-approved descaler and a proper clean-down are within reach for some operators, but incorrect chemicals or a skipped sanitising step can damage the plate or leave residue. Servicing also catches faults that a clean will not.
Why is my ice cloudy?
Usually water quality, a spent filter, scale on the plate or a slow harvest. Cloudy ice is rarely a refrigerant fault.
Do you service under-counter machines?
Yes, including under-counter units in home bars, guest houses and small cafés as well as larger modular machines.